DUAL SHIELD R-70 Ultra

Dual Shield R-70 Ultra is a low fuming flux cored wire with a balanced chemistry .

Features

Dual Shield R-70 Ultra is a low fuming flux cored wire with a balanced chemistry that allows for a greater tolerance of mill scale and surface oxides than is normally associated with an E70T-1 class of wire. The "Ultra" series produces smoother arc characteristics and lower welding fumes than non-ultra types. Notch toughness in the as welded condition is also improved with this wire. Bead contour is flat to slightly convex and slag coverage is complete. Dual Shield R-70 Ultra wire is designed for single or multipass applications on low or medium carbon steels. It is intended for use in the flat and horizontal positions with 100% CO2 or 75%Argon / 25% CO2 shielding gas. Areas of application include railcar, heavy equipment, and general fabrication.

Dual Shield R-70 Ultra
  • Industry
  • General Fabrication
  • Civil Construction
  • Shipbuilding
  • Mobile Machinery
  • Rail Road Car
  • Welding Process
  • FCAW (Flux Core)

Classifications

  • Classifications/Approvals

    • L.R.- 2S,2YS(H15)
    • D.N.V.- II YMS(H15)
    • CERTIFIED BY C.W.B.- CSA W48
    • ASME SFA 5.20
    • AWS A5.20; E70T-1CH8/T-1M/T-9CH8/T-9M
    • QPL-24403/1; MIL-70T-1C
    • A.B.S.- 2SA,2YSA

Properties

Typical Properties
As Welded CO2  
Yield Strength 70 ksi, 485 MPa
Tensile Strength 82 ksi, 565 MPa
Reduction in Area 63 %
Elongation in 2" 26 %
Typical Charpy V-Notch Impact Properties  
Testing Temperature 0ºF (-18ºC)  
As Welded CO2 28 ft.-lbs., 38 J
Testing Temperature -20ºF (-29ºC)  
As Welded CO2 25 ft.-lbs., 34 J
Typical Undiluted Weld Metal Analysis  
CO2  
C 0.02 %
Mn 1.4 %
Si 0.5 %
P 0.014 %
S 0.008 %

SAW

Accessories

Depositions

Extra Info

Shielding Gas

CO2