Print this page

ARCALOY 309/309H-15

Arcaloy 309/309H-15 is used for welding type 309 when high temperature service is required. Best used out-of-position on DC current.

Features

Arcaloy 309/309H-15 is used for welding Type 309 base metal for all service temperatures designed for Type 309. It can be used for carbon and low alloy steel to stainless steel joints.

* This item is subject to Industry Alloy Surcharges

Arcaloy 309/309H-15
  • Industry
  • Process
  • General Fabrication
  • Petrochemical
  • Welding Process
  • SMAW (Stick)

Classifications

  • Classifications/Approvals

    • QPL-22200/2; MIL-309-15
    • ASME IX F No. 5
    • AWS A5.4; E309/309H-15
    • ASME II SFA E309-15

Properties

Typical Properties
Yield Stress 55 ksi, 380 MPa
Tensile Strength 90 ksi, 620 MPa
Elongation in 2" 40 %
Typical Undiluted Weld Metal Analysis  
C 0.06 %
Mn 1.8 %
Si 0.5 %
Cr 23.5 %
Ni 13.5 %
Mo 0.1 %
Cu 0.1 %
Ferrite 7 FN

Part No.

309/309H-15
Part No. Model / Product Description UPC
251055927 AC 309/309H-15 1/8X14X10#HS 662303013417
251055976 AC 309/309H-15 5/32X14X10#HS 662303040987
251055992 AC 309/309H-15 3/32X12X10#HS 662303074630

SAW

Accessories

Depositions/Paramaters

Welding Parameters
Diameter Flat Vertical Overhead
1/16 in., 1.6 mm 20-35 Volts 15-25 Volts 20-30 Volts
5/64 in., 2.0 mm 30-50 Volts 25-35 Volts 30-40 Volts
3/32 in., 2.4 mm 40-70 (Plus 60-85) Volts 35-50 (40-60) Volts 40-60 Volts
1/8 in., 3.2 mm 65-100 (Plus 90-120) Volts 55-70 (70-80) Volts 60-85 Volts
5/32 in., 4.0 mm 100-145 (Plus 140-165) Volts 85-100 (80-90) Volts 95-120 Volts
3/16 in., 4.8 mm 130-190 (Plus 180-210) Volts 100-115 Volts 125-150 Volts
1/4 in., 6.4 mm 205-290 Volts

Extra Info

Arcaloy 309/309H-15 electrodes are used for welding Type 309 and similar stainless steels for higher temperature service. In these applications, greater strength is required and a limited quantity of ferrite. They can also be used to weld low alloy to stainless steel dissimilar joints where a lower ferrite content is desired and is acceptable. In the latter case, the service temperature should not exceed 700ºF (370ºC). The basic coating of Arcaloy 309/309H-15 gives the highest resistance to cracking and excellent vertical welding characteristics. It is therefore the choice for field welding.