Oxweld High Capacity Industrial Gas Regulators can be used in multiple units installed in parallel.

| Oxygen Gas Service Regulators | |
|---|---|
| Inlet and Outlet Connection | 3/4 in. or 2 in. NPT |
| Maximum Inlet Pressure | 350 PSIG |
| Maximum Delivery Pressure | 150 or 200 PSIG |
| Rated Capacity | 10,000 or 40,000 CFH |
| Acetylene Gas Service Regulators | |
| Inlet and Outlet Connection | 3/4 in. NPT |
| Maximum Inlet Pressure | 15 PSIG |
| Maximum Delivery Pressure | 12 PSIG |
| Rated Capacity | 2,000 CFH |
| Fuel Gas Service Regulators | |
| Inlet and Outlet Connection | 3/4 in. NPT |
| Maximum Inlet Pressure | 150 or 350 PSIG |
| Maximum Delivery Pressure | 40 PSIG |
| Rated Capacity | 8,000 or 3,000 CFH |
| There are no accessories. |
|---|
In most instances, capacity is much higher than listed. This will depend upon outlet pipe/hose restrictions. Consult ESAB for recommendations.